DYNAMIC LOAD TEST/PILE DYNAMIC ANALYZIS (PDA)


  Since the SLT requires a week or more to obtain the result, a quicker load testing method (DLT) sometimes is applied which is based on stress-wave theory. – Using this method, around 4 piles could be tested perday. However, the results of this testing method have to be calibrated to the result of SLT of a pile near to the pile tested by this DLT method for increasing its accuracy.
  Application of this DLT requires a drop hammer with a minimum weight 2% of the design ultimate load capacity of pile to be dropped on the surface of pilehead to generate the stress-wave which is then recorded and calculated by a computer. TENO INDONESIA provide this testing equipments from DYNAMIC LOAD INSTITUTE (DFI) from USA. Pile integrity test good also be carry out with the same equipments.





ADDRESS

OFFICE
  Graha Teno

Jl. Raya Kertajaya Indah 153/P-116
Surabaya 60116 - Indonesia
Telp : (031) 593 6240-42
Fax : (031) 593 6243
  E-mail : tenoindo@gmail.com